JDL-50–240 Insulated Grounding Clamp for 10kV Overhead Lines

The JDL-50–240 insulated grounding clamp provides a fixed grounding and discharge connection point on overhead insulated conductors rated up to 10kV. Its high-strength aluminium-alloy conductive body is combined with an insulated grounding ring and bolted conductor clamp.

The representative JDL-50–240 model covers 50–240 mm² conductors. Conductor diameter, connection orientation, installation torque and short-circuit requirements must be confirmed according to the approved line design before ordering.

JDL-50–240 Insulated Grounding Clamp for 10kV Overhead Lines

The JDL insulated grounding clamp is designed to provide a fixed grounding, voltage-testing and discharge connection point on overhead insulated distribution lines rated up to 10kV. It allows approved temporary grounding equipment to be connected during line maintenance after the circuit has been isolated, de-energized and verified according to the applicable utility safety procedure.

The clamp combines a high-strength aluminium-alloy conductor clamp with an insulated rectangular grounding ring. A controlled exposed metal contact section provides the connection point for compatible temporary grounding equipment, while the insulated sections reduce unintended contact with the conductive ring.

Reference Technical Data

Product Type Insulated Grounding Clamp / Grounding Ring
Reference Model JDL-50–240
Rated Line Voltage Up to 10kV
Reference Conductor Range 50–240 mm²
Application Overhead insulated distribution conductors
Clamp Body Material High-strength aluminium alloy
Insulating Material Silicone-rubber insulating cover
Reference AC Withstand of Insulating Cover ≥18kV
Installation Method Bolted conductor clamp
Connection Orientation Straight and side-connection versions available
Standard Colour Black
Optional Colours Red, yellow and green, subject to order confirmation

Important: The JDL-50–240 specification is a representative configuration. Final product selection must be based on conductor material, conductor diameter, insulation thickness, installation orientation, required contact interface and the approved utility drawing.

Key Features

  • Provides a fixed connection point for temporary grounding and discharge operations
  • Suitable for overhead insulated distribution lines rated up to 10kV
  • High-strength aluminium-alloy body provides electrical conductivity with reduced weight
  • Insulated rectangular grounding ring limits unnecessary exposure of the conductive section
  • Bolted clamp structure supports secure mechanical contact with the conductor
  • Available for different conductor ranges and connection orientations
  • Silicone-rubber insulating components provide electrical insulation and outdoor weather resistance
  • Colour options can support phase identification or project-specific requirements

Materials and Construction

Conductive Clamp Body High-strength aluminium alloy
Grounding Ring Metal conductive ring with partial insulating coverage
Insulating Cover Silicone rubber
Clamp Plate Metal conductor-contact component according to the approved drawing
Bolts and Nuts Material and corrosion protection according to the approved production specification
Surface Protection Conductive and fastener surfaces supplied according to the project environment and approved drawing

Applications

  • 10kV overhead insulated distribution lines
  • Rural electrification and distribution-network upgrades
  • Utility line inspection and maintenance grounding points
  • Temporary grounding connection after line isolation
  • Voltage-testing and discharge connection points
  • Industrial and utility overhead power networks

Available Reference Models

Reference Model Conductor Range Connection Type
JDL-25–120 25–120 mm² Straight or side connection
JDL-50–240 50–240 mm² Straight or side connection

Information Required for Selection

  • System rated voltage
  • Conductor material and cross-sectional area
  • Overall conductor diameter
  • Insulation material and thickness
  • Straight or side-connection configuration
  • Required installation torque
  • Required short-circuit current and duration
  • Grounding equipment contact dimensions
  • Insulation colour requirements
  • Applicable utility standard and test-document requirements

Installation and Safety

This product is intended to provide a grounding connection point and must not be treated as a complete grounding system by itself. Installation, inspection and temporary grounding operations must be performed by qualified personnel using approved equipment and utility procedures.

The line must be isolated, de-energized, secured against reconnection and tested for absence of voltage before temporary grounding equipment is connected. Installation torque and conductor preparation must follow the approved product drawing. Do not describe the clamp as an insulation-piercing model unless the supplied product has a verified piercing structure.

Standards and Testing

IEC 61230 applies to portable equipment, including matching connection points, used for temporary earthing or earthing and short-circuiting of isolated or de-energized electrical installations. Compliance with IEC 61230 must only be claimed when the complete grounding equipment or relevant component has been tested and supported by valid documentation.

Mechanical strength, contact resistance, temperature rise, short-circuit withstand and insulation performance should be confirmed according to the purchaser’s technical specification and the approved test report.

Frequently Asked Questions

Is the JDL grounding clamp an insulation-piercing connector?

Not necessarily. Standard JDL grounding clamps and piercing grounding connectors are different product structures. Conductor preparation must be confirmed from the actual product drawing before installation.

Can the clamp be used while the conductor is energized?

It is intended as a connection point for approved temporary grounding equipment after the electrical installation has been isolated, de-energized and tested for absence of voltage. It must not be promoted as a live-line grounding device without specific certification and procedures.

How is the correct model selected?

Selection is based on conductor cross-section, conductor diameter, insulation construction, connection orientation and project requirements. Cross-sectional area alone is not sufficient for final confirmation.

Is this product a lightning arrester?

No. It provides a grounding and discharge connection point. It should not be described as an independent lightning arrester unless it forms part of a separately designed and tested lightning-protection assembly.

Can the insulation colour be customized?

Black is commonly supplied, while red, yellow and green versions may be available for phase identification or project requirements.

Brand

JIUJIN POWER

Reference Model

JDL-50–240

Product Type

Insulated Grounding Clamp

Alternative Name

Voltage Testing and Grounding Ring

Rated Voltage

Up to 10kV

Conductor Range

50–240 mm²

Conductor Type

Overhead Insulated Conductor

Clamp Body Material

High-Strength Aluminium Alloy

Insulating Material

Silicone Rubber

Insulation Withstand

≥18kV AC, Reference Value

Installation

Bolted Clamp

Connection Type

Straight / Side Connection

Colour

Black

Optional Colours

Red / Yellow / Green

Application

Temporary Grounding Connection Point

Reference Standard

IEC 61230, Subject to Test Documentation

Customization

Conductor Range / Orientation / Colour