35kV Three-Core Outdoor Heat Shrink Cable Termination Kit

The 35kV three-core outdoor heat shrink cable termination kit is designed for terminating screened three-core polymeric-insulated power cables in outdoor medium-voltage distribution systems. It uses electrical stress-control components, anti-tracking phase tubes, rain sheds, sealing materials and an adhesive-coated breakout to provide insulation, environmental sealing and an extended creepage path.

The reference 35kVRSWY-3/3 configuration covers 150–240 mm² conductors. Final kit selection must be confirmed according to cable insulation diameter, conductor size, screen construction, armour type and terminal lug requirements.

35kV Three-Core Outdoor Heat Shrink Cable Termination Kit

The 35kV three-core outdoor heat shrink cable termination kit is designed for the outdoor termination of screened three-core polymeric-insulated medium-voltage power cables. It provides electrical stress control, phase insulation, environmental sealing and an extended surface creepage path at the cable termination point.

The kit is suitable for connecting three-core power cables to outdoor switchgear, transformers, cable termination structures and other medium-voltage electrical equipment. Each phase is protected by an anti-tracking heat shrink tube and multiple rain sheds, while the cable crutch area is sealed with an adhesive-coated breakout component.

Reference Configuration

Product Type Three-Core Outdoor Heat Shrink Cable Termination Kit
Reference Model 35kVRSWY-3/3
Voltage Class 35kV class
Reference Rated Voltage 26/35kV
Number of Cable Cores 3 cores
Reference Conductor Range 150–240 mm²
Compatible Cable Insulation XLPE or other screened polymeric insulation, subject to cable dimensions
Conductor Material Copper or aluminium
Installation Environment Outdoor
Reference Installed Length Approximately 1100 mm
Reference Dimension D Approximately 140 mm
Rain Sheds 18 pieces total for the three-phase assembly
Terminal Lugs Optional; selected separately according to conductor material and equipment interface

Important: The dimensions and conductor range above describe a representative configuration. Final selection must be based on the actual diameter over cable insulation, conductor cross-section, metallic screen, armour construction and terminal interface.

Key Features

  • Designed for outdoor termination of screened three-core medium-voltage power cables
  • Electrical stress-control tube and stress-relief mastic help control the electric field at the screen cut
  • Anti-tracking heat shrink phase tubes provide phase insulation and surface protection
  • Multiple rain sheds extend the creepage path for outdoor service
  • Adhesive-coated breakout seals and protects the three-core cable crutch area
  • Heat-activated sealing components help limit moisture entry at critical interfaces
  • Suitable for copper or aluminium conductors when fitted with the corresponding terminal lugs
  • Different kits are available for conductor size, insulation diameter, cable screen and armour construction

Materials and Construction

Anti-Tracking Tubes and Rain Sheds Heat-shrinkable anti-tracking polymer
Electrical Stress-Control Components Stress-control tube and stress-relief mastic
Cable Breakout Adhesive-coated heat-shrink breakout component
Environmental Sealing Heat-activated sealing tubes and sealing mastic
Earthing Components Selected according to the cable metallic screen and armour construction
Terminal Lug Tinned copper or copper-aluminium lug according to conductor and equipment requirements; normally ordered separately
Surface Protection Weather-resistant and anti-tracking heat-shrink insulation; metal lug finish is specified separately

Applications

  • 35kV outdoor power cable termination
  • Medium-voltage distribution networks
  • Outdoor transformer cable connections
  • Substation cable termination structures
  • Outdoor switchgear and electrical equipment connections
  • Industrial power distribution systems
  • Wind and solar power collection systems
  • Utility and infrastructure cable projects

Cable Selection Information Required

To select the correct termination kit, please provide the following cable information with your inquiry:

  • Rated cable voltage
  • Number of cable cores
  • Conductor material and cross-sectional area
  • Diameter over conductor insulation
  • XLPE or other insulation material
  • Copper wire screen, copper tape screen or other screen construction
  • Armoured or unarmoured cable construction
  • Required terminal lug type and palm-hole dimensions
  • Applicable project standard and test-document requirements

Standards and Testing

For 26/35kV cable systems with a maximum system voltage above 36kV, IEC 60840 is the relevant IEC reference for cables and accessories. Compliance must only be stated when the supplied product is supported by the corresponding type-test report or project-approved documentation.

IEC 60502-4 applies to cable accessories only up to 18/30(36)kV and should not automatically be claimed for a 26/35kV termination kit.

Ordering Information

Please confirm the cable datasheet or provide the cable model, rated voltage, conductor size, insulation diameter, screen construction and armour type before ordering. Terminal lugs, earthing components and installation accessories can be configured according to the approved cable and equipment drawings.

Frequently Asked Questions

Is this termination suitable for 26/35kV XLPE cable?

It can be configured for screened 26/35kV three-core XLPE power cable. Final compatibility depends on the cable insulation diameter, screen design, armour construction and conductor size.

Can the kit be selected only by conductor cross-section?

No. Conductor cross-section is a preliminary reference. The diameter over insulation and the complete cable construction must also be checked before confirming the kit.

Are cable lugs included?

Terminal lugs are normally selected separately because copper and aluminium conductors require different lug materials and equipment interfaces. Please confirm the required lug type when requesting a quotation.

Why are rain sheds used on the outdoor termination?

The rain sheds increase the surface creepage path and support outdoor insulation performance under rain, dust and other environmental exposure.

Can the kit be supplied for armoured cable?

Yes, but the armour type and earthing arrangement must be confirmed so that the appropriate sealing and grounding components can be supplied.

Brand

JIUJIN POWER

Reference Model

35kVRSWY-3/3

Product Type

Outdoor Heat Shrink Cable Termination Kit

Voltage Class

35kV

Rated Voltage

26/35kV

Number of Cores

3

Conductor Size

150–240 mm²

Cable Insulation

Screened XLPE / Polymeric Insulation

Conductor Material

Copper / Aluminium

Installation

Outdoor

Stress Control

Stress-Control Tube and Mastic

Insulation Material

Anti-Tracking Heat-Shrink Polymer

Rain Sheds

18 Pieces Total

Reference Length

1100 mm

Reference Dimension D

140 mm

Cable Construction

Confirm According to Cable Datasheet

Terminal Lugs

Optional / Ordered Separately

Application

Medium-Voltage Power Cable Termination

Reference Standard

IEC 60840, Subject to Test Documentation

Scroll to Top